Aluminum Wiring Repair in Calgary

How You Can Keep Your Family Safe From The Dangers Of Aluminum Wiring Without Ripping Out Your Walls ... I'll likewise show you how to repair it without investing a truckload of money doing it.

If your house was constructed throughout the late sixties to the mid seventies, there is a great chance that aluminum circuitry was used instead of copper for its electrical circuits. Aluminum was used because there was a scarcity of copper due to the Vietnam War.

However, over time, problem emerged - particularly ... houses were burning down with the aluminum connections to devices - outlets and switches - as the cause. As a matter of truth, research study carried out by Franklin Research Institute for Consumer Product Safety Commission (CPSC) revealed that houses constructed with aluminum circuitry are 55 times most likely to catch fire than homes wired with copper. There is nothing wrong with the aluminum itself. It is an outstanding conductor and less pricey than copper. The issues arise since aluminum expands and contracts far faster than copper when utilized. This can trigger a loose connection, developing gaps that can cause sparking and fire. Intensifying the problem further is the fact that aluminum nearly instantly starts to oxidize the minute it is exposed to the oxygen in our air. This response forms an oxide coating on the wire just like rust types on iron.

This oxide minimizes the capability for the wire to perform electricity resulting in even more heat. Eventually, it can become hot enough to melt or burn fixtures - such as wall outlets and changes - where the exposed aluminum is in contact with the brass connections. So the problem is the exposed aluminum around the connections - and the connections themselves. When considered to be unsafe in 1974, aluminum wiring was all however stopped in house applications. Unfortunately, it was too late for the homes already installed with it.

If your house is fitted with aluminum circuitry, you can be facing other problems aside from the obvious threat of fire. Some insurance provider will not guarantee homes with aluminum circuitry unless it is upgraded to present day electrical code. This can cause untimely and undesirable financial responsibilities if you were trying to sell your home or get your restorations gone by a government inspector. Furthermore, if your insurance provider discovers that a fire in your house was triggered by aluminum wiring connections, they might decline your claim for monetary compensation. Now there are a number of solutions to this bad situation, however the very first thing you need to do is determine if you have aluminum circuitry to start with. You can get an electrical specialist managed by a master electrical expert to take a look at it for you.

However the simplest way to do this is to look at the printed or embossed markings on the outer jacket of the electric circuitry, which show up in incomplete walls or ceilings in basements, attics, or garages. Cable with aluminum conductors will have "Al" or "Aluminum" and other information marked on one side of the cable coat every couple of feet along its length. If for whatever factor, you can not see any circuitry, then there is another, albeit a bit more involved method of checking.

Here are the 3 easy steps:

Action 1 - plug a hair clothes dryer or light into any wall outlet, turn it on and leave it on.

Step 2 - go to your circuit panel and journey (switch off) the breaker representing that outlet. You'll know you have the right breaker when your hair dryer or light is off when you inspect back on it.

Step 3 - disconnect the device and eliminate the outlet from the wall and check the circuitry attached to it. DO NOT DETACH THE ELECTRICAL WIRING. You can make the connection worse if you do.

You need to have the ability to see the bare wire beneath the screws. It is easy to recognize aluminum since of its colour. If you an orange color, this is copper. However, if the exposed wire beneath the screws is white, it is aluminum. Got it?

alumiconn